0% Complete
English
صفحه اصلی
/
سی و دومین کنفرانس ملی و دهمین کنفرانس بین المللی مهندسی زیست پزشکی ایران
Gait-Triggered Neuromuscular Electrical Stimulation with Unloader Knee Braces: A Feasibility Study
نویسندگان :
Mohadeseh Jafarian
1
Reza Khosrozadeh Sarijalou
2
Amin Komeili
3
Kourosh Barati
4
Navid Arjmand
5
1- Department of Mechanical Engineering, Sharif University of Technology, Tehran, Iran
2- Department of Mechanical Engineering, Sharif University of Technology, Tehran, Iran
3- Department of Biomedical Engineering, University of Calgary, Calgary, Canada
4- Department of Orthotics and Prosthetics, School of Paramedical Sciences, Mashhad University of Medical Sciences, Mashhad, Iran
5- Department of Mechanical Engineering, Sharif University of Technology, Tehran, Iran
کلمات کلیدی :
Knee osteoarthritis،Unloader brace،Neuromuscular electrical stimulation (NMES)،Gait event detection
چکیده :
Objective. Knee osteoarthritis (OA) commonly involves the medial compartment of the joint. Valgus unloader braces can reduce joint loading in this region but may also suppress quadriceps activation. Neuromuscular electrical stimulation (NMES) can strengthen quadriceps when voluntary activation is limited. We evaluated the feasibility of a gait-triggered NMES system used in combination with a valgus unloader brace. Methods. A portable module was developed incorporating a commercial NMES stimulator, a microcontroller, and an inertial measurement unit (IMU). Gait events (mid-swing, initial contact, and toe-off) were detected in real time to trigger quadriceps stimulation. The system was tested in eight adults with medial knee OA and five healthy controls, each completing a 30-minute supervised walking session. Results. The device operated continuously throughout all sessions. In patients with OA, mean cadence was 1.14 ± 0.39 steps·s⁻¹ with cycle detection accuracy of 91.2 ± 8.2%. In healthy controls, cadence was 2.01 ± 0.44 steps·s⁻¹ with accuracy of 93.2 ± 4.3%. No serious adverse events occurred. Conclusion. The proposed brace-compatible, gait-triggered NMES system is feasible, safe, and well tolerated. This proof-of-concept provides a foundation for future works on miniaturization, algorithm refinement, and multi-week clinical trials.
لیست مقالات
لیست مقالات بایگانی شده
Effect of Aimlabs Software on Sustained Attention, Reaction Time, and Hand-Eye Coordination in Stroke Patients: A Preliminary Study
SEYEDALI BAGHERZADEH - Leyla Rastgar-Farajzadeh
Using Advanced Ensemble Machine Learning Models to Predict Traffic in SDN-Based Networks: A Comparative Study of Bagging, Boosting, and Stacking Approaches
Raha Pakzad - Sasan GharaPasha - Nasrin Firouz - Ramin Habibzadehsharif
طراحی یک سیستم تشخیص سطح لرزش برای بیماران پارکینسون بر اساس توپولوژی سری زمانی لرزش در فضای فاز جغرافیایی
مهدی ذوالفقارزاده کرمانی - سعید رشیدی - اساسه مریم
تاثیر کوته بینی مدیریتی بر عملکرد پایداری شرکت با تاکید بر هزینه های نمایندگی
رعنا شهدآور - مهدی پورعلی
ارزیابی ساختار بازار حسابرسی در ایجاد ارزش افزوده اقتصادی در صنعت فولاد
کریم ستاری - محمدرضا عباسی استمال
ارائه یک مدل ARIMAX بهبود یافته برای پیش بینی قیمت سهام
عارفه عمیدیان - امیرمسعود عمیدیان - مینا مسعودی فر
بررسی تاثیر کیفیت خدمات، ارزش درک شده و تصویر شرکت بر رویکرد نگرشی مشتریان در بانکداری
امیر محمدپور - یاسین فخیم عبدالهی - محمد همت زاده
نظریه بازی در کارآفرینی: مروری بر ادبیات
رعنا شهدآور - فاطمه اصدقی - فائزه فتحی
بکارگیری فن آفرینی های پیشرفته جهت شناسایی خانه های خالی با اهداف مالیات گیری
جابر خورشیدسوار - جمال برزگری خانقاه
بررسی تأثیر ارائه صورت تغییرات حقوق مالکانه بر کیفیت اطلاعات حسابداری
سید علی میرنژاد - جمال برزگری خانقاه - فاطمه زه تابیان یزدی
بیشتر
ثمین همایش، سامانه مدیریت کنفرانس ها و جشنواره ها - نگارش 42.4.1