0% Complete
فارسی
Home
/
سی و دومین کنفرانس ملی و دهمین کنفرانس بین المللی مهندسی زیست پزشکی ایران
Patient-Specific TMJ Implants: A Finite Element Study on Placement and Material Effects
Authors :
Aryana Tavakoulnia
1
Mohadese Rajaeirad
2
Nima Jamshidi
3
Sandipan Roy
4
1- University of Isfahan
2- University of Isfahan
3- University of Isfahan
4- SRM institute of technology
Keywords :
Temporomandibular Joint،Finite Element Analysis،Patient-Specific Prosthesis،Stress Distribution،PEEK،Titanium
Abstract :
The clinical success and long-term durability of total temporomandibular joint (TMJ) prostheses are directly dependent on mechanical stability and the pattern of biomechanical force distribution between the prosthesis and the host bone. Factors such as precise implant positioning and the mechanical properties of the prosthesis material play a critical role in its performance. This computational study aims to quantitatively and comparatively investigate the effect of the prosthesis's positioning and material on stress distribution and mechanical stability using the finite element method. A 3D model of a patient's mandible was reconstructed from high-resolution CT scans, and a patient-specific total joint prosthesis was designed. Two materials were considered: Titanium alloy (Ti-6Al-4V) and Polyetheretherketone (PEEK). For each material, three positioning scenarios were defined: (1) an ideal anatomical reference position, (2) a 2 mm lateral displacement, and (3) a 3 mm medial displacement. The bone-prosthesis assemblies were analyzed in Abaqus under a static chewing load of 262.28 N. The results showed that prosthesis positioning significantly impacts the stress distribution pattern. For the titanium model, the lateral position was identified as biomechanically optimal, as it best protected the host bone from excessive loading while ensuring maximum structural stability. A comparison of materials revealed that while titanium prostheses offer greater stability (less displacement), PEEK prostheses, due to an elastic modulus closer to that of bone, reduce the stress shielding phenomenon and lead to a more physiological load distribution on the bone. The final choice of material depends on prioritizing maximum stability versus the long-term health of the host bone.
Papers List
List of archived papers
A Novel AR-Based Kalman Filtering Framework for ECG Enhancement
Hamed Danandeh Hesar
بررسی تأثیر سبک نگارش بر نحوه بازیابی پاسخ توسط مدلهایزبانیبزرگ با استفاده از ژئومتریک
مینا زالی - مریم شفائی - فاطمه فاقعی شهربابکی
Physics-Informed Neural Networks for Cardiac Flow Estimation in 2D Simplified Human Right Ventricular Geometry
Mohammadmahdi Sekhavatpisheh - Nasser Fatouraee
A Quantitative Approach to Assess Rhus coriaria Nanophytosomes in Ketamine-Induced Liver Injury
Narjes Amin - Akbar Hajizadeh Moghadam - Amin Mohammad Mohammadi - Kimia Mozahheb Yousefi - Fereshteh Mir Mohammadrezaei - Sedigheh Khanjani Jelodar
تبیین روابط بین ،استراتژی مالی رقابتی ، توانمندی های بازاریابی و عملکرد سرمایهگذاری صادراتی با تکیه بر دیدگاه مبتنی بر منابع
حسین بوذری
رویکردهای مدیریت مالی با استفاده از فناوریهای هوشمند
حسن هاتف - سید محمد عالی نژاد - سید جبار عالی نژاد
مدل های نوین بودجه ریزی عملیاتی و نقش آنها در بهبود عملکرد مالی بانک ها
بهارک یادگار جمشیدی - مبینا مولایی
ارتباط بین روابط سیاسی و افشای مسئولیت پذیری اجتماعی شرکت
بیتا دلنواز اصغری - مهنا پیرایه جو - نیما رضااوغلی سقا - مائده خاکسار
Experimental Framework for Quantifying Muscle Force-Length Behavior in Dynamic Exercise
Erfan Farahani - Manizheh Zakeri - Mohammad-Reza Sayyed Noorani
بهبود طبقه بندی احساسات نظرات مشتریان آمازون با جنگل تصادفی
فائزه مختارآبادی - وحید خطیبی بردسیری
more
Samin Hamayesh - Version 42.4.1