Please wait ...
0% Complete
فارسی
Home
/
سی و دومین کنفرانس ملی و دهمین کنفرانس بین المللی مهندسی زیست پزشکی ایران
Patient-Specific TMJ Implants: A Finite Element Study on Placement and Material Effects
Authors :
Aryana Tavakoulnia
1
Mohadese Rajaeirad
2
Nima Jamshidi
3
Sandipan Roy
4
1- University of Isfahan
2- University of Isfahan
3- University of Isfahan
4- SRM institute of technology
Keywords :
Temporomandibular Joint،Finite Element Analysis،Patient-Specific Prosthesis،Stress Distribution،PEEK،Titanium
Abstract :
The clinical success and long-term durability of total temporomandibular joint (TMJ) prostheses are directly dependent on mechanical stability and the pattern of biomechanical force distribution between the prosthesis and the host bone. Factors such as precise implant positioning and the mechanical properties of the prosthesis material play a critical role in its performance. This computational study aims to quantitatively and comparatively investigate the effect of the prosthesis's positioning and material on stress distribution and mechanical stability using the finite element method. A 3D model of a patient's mandible was reconstructed from high-resolution CT scans, and a patient-specific total joint prosthesis was designed. Two materials were considered: Titanium alloy (Ti-6Al-4V) and Polyetheretherketone (PEEK). For each material, three positioning scenarios were defined: (1) an ideal anatomical reference position, (2) a 2 mm lateral displacement, and (3) a 3 mm medial displacement. The bone-prosthesis assemblies were analyzed in Abaqus under a static chewing load of 262.28 N. The results showed that prosthesis positioning significantly impacts the stress distribution pattern. For the titanium model, the lateral position was identified as biomechanically optimal, as it best protected the host bone from excessive loading while ensuring maximum structural stability. A comparison of materials revealed that while titanium prostheses offer greater stability (less displacement), PEEK prostheses, due to an elastic modulus closer to that of bone, reduce the stress shielding phenomenon and lead to a more physiological load distribution on the bone. The final choice of material depends on prioritizing maximum stability versus the long-term health of the host bone.
Papers List
List of archived papers
2D Residual U-Net for Accurate Lumbar Vertebrae Segmentation in MRI-Based Low Back Pain Diagnosis using the SPIDER Dataset
Armita Rahimi Borgi - Abdollah Zohrabi - Ali Kazemi - Mostafa Abdolghaffar - Ramin Kordi - Parastoo Farnia - Alireza Ahmadian
بررسی تأثیر ابعاد سه گانه سرمایه فکری بر عملکرد مالی سازمان منطقه آزاد تجاری و صنعتی ماکو
فرشید میابی - المیرا گوهری بوکت
Multi-View 2.5D Attention U-Net with 3D Fusion for Efficient Stroke Lesion Segmentation from T1-Weighted MRI
Fatemeh Salahshourinejad - Kamran Kazemi - Negar Noorizadeh - Mohammad Sadegh Helfroush - Ardalan Aarabi
پایداری، مسئولیت و اخلاق: مفاهیم مختلف برای یک مسیر واحد
رعنا شهدآور - ثمین مقیمی - فاطمه حسنی
Quantum Computing for AI: Current Status and Future Roadmap
Nayereh Majd
شناسایی و تفکیک خودکار ضایعات بیماری مولتیپل اسکلروزیس در MRI با استفاده از معماری بهینه شده U-NET
مریم فتحعلی زاده اصل سرکندی - علی پورقاسم
Addressing Class Imbalance Using Difficulty-based Oversampling with Variance Control
Zahra Asgharzadeh Bonab - Sina Shamekhi
تحلیل اثر انشعاب فیبر بر خواص مکانیکی تاندون در محل اتصال به استخوان
فاطمه شهماری میکائیل درسی - هادی تقی زاده
بررسی رابطه مدیریت سرمایه در گردش با عملکرد مالی در بورس اوراق بهادار تهران
علی مبارکی
Effect of ph changes on thermal and mechanical properties of polyacrylamide hydrogel using molecular dynamics simulation
Narges Karimzadeh Dehkordi
more
Samin Hamayesh - Version 44.7.0