Functionally Graded Material Vertebroplasty Screws: A Finite Element Biomechanical Study
Authors :
Maryam Rahimi
1
Mohammad Hosein Zadeh-Posti
2
َAisan Rafiei
3
Nima Jamshidi
4
1- University of Isfahan
2- University of Guilan
3- Iran University Of Science & Technology
4- University of Isfahan
Keywords :
vertebroplasty،functionally graded materials،finite element analysis،hydroxyapatite،biomechanical compatibility
Abstract :
Vertebroplasty is a minimally invasive treatment for osteoporotic vertebral compression fractures (VCFs), yet conventional titanium screws often induce stress shielding and poor load transfer. This study evaluates the biomechanical performance of a novel functionally graded material (FGM) vertebroplasty screw—comprising a Ti-6Al-4V core and hydroxyapatite (HAP) outer layer—using finite element analysis (FEA. A 3D model of the L2 vertebra was reconstructed from CT data and meshed with over 250,000 elements. Two screw types (homogeneous titanium vs. FGM) were simulated under a 300 N axial load. The FGM screw’s radial stiffness gradient was defined by a power-law distribution and implemented via a UMAT subroutine in ABAQUS. Results showed a 14% reduction in peak von Mises stress (12.19 MPa vs. 10.45 MPa) and a 32% decrease in maximum elastic micro-strain (179.9 vs. 121.5) in the FGM screw. Cortical bone stress remained constant (52.20 MPa), while cancellous bone displacement decreased by 36% in the anteroposterior direction (0.02671 mm vs. 0.01702 mm), indicating improved primary stability. Displacement differences between screw types were negligible (<0.00008 mm across all axes), confirming construct integrity. Validation against prior studies showed <10% deviation in stress metrics. The FGM design redistributed internal loads, reduced stress concentrations, and enhanced biomechanical compatibility without compromising cortical integrity. These findings support the potential of graded screws to improve vertebroplasty outcomes by minimizing implant loosening and promoting osseointegration.
Papers List
List of archived papers
Plasma Electrolytic Oxidation-Derived HAp–Ta₂O₅ Coatings on Ti6Al4V for Biomedical Applications
Milad Hosseini - Jafar Khalil allafi - Mir saman Safavi
How Geometric Asymmetry Impacts Aortic Valve Bioprosthesis Performance – A Finite Element Analysis
Reyhaneh Mosaferchi - Nasser Fatouraee
طراحی آتل شخصی سازی شده با روش نیمه خودکار پردازش تصاویر DICOM
محمدمهدی صفاری - محمدرضا سجادی
تاثیر داراییهای نامشهود بر ارزش بازار شرکت؛ مطالعه موردی شرکت های صنایع شیمیایی بورس اوراق بهادار تهران
محمدرضا پژوهی
Early Alzheimer’s Detection with MRI-Based Deep Convolutional Neural Networks and Transfer Learning
Tabasom Musavi - M. J. Tarokh
Dual-View Data Representation and Contrastive Learning for Robust EEG-Based Person Identification
Mahdi Tabatabaei - Mohammad Bagher Shamsollahi
The Influence of Insertion-Induced Prestress and Viscoelastic Properties in Fixational Stability of Pedicle Screws in UHWMPE block: A Finite Element Study
Ahmad Babazadeh Gh - Mohammadjavad (Matin) Einafshar - Ata Hashemi
شناسایی و رتبه بندی عوامل موفقیت در بهبود فروش در مدیریت زنجیره تأمین پنجرههای upvc با استفاده از AHP فازی Fuzzy
محمد اخشابی
تاثیر هوش مصنوعی در کیفیت خدمات آنلاین بانکی
بهارک یادگار جمشیدی - زهرا شرقی
بررسی تاثیر کیفیت خدمات، ارزش درک شده و تصویر شرکت بر رویکرد نگرشی مشتریان در بانکداری
امیر محمدپور - یاسین فخیم عبدالهی - محمد همت زاده
more
Samin Hamayesh - Version 44.7.0